dc.description.abstractThe quality of biological samples for Transmission Electron Microscopy prepared using High Pressure Freezing and Freeze Substitution with a novel agitation module invented by Helmuth Goldhammer and Siegfried Reipert was compared to Cells prepared without agitation and the Freeze Substitution protocol by Obornik et al. The amount of extraction was quantified via immunolabelling of RuBisCO inside the plastids of the Alveolate Chromera Velia Mechanical Damages were quantified by counting of obviously damaged and intact cells at low magnificationcze
dc.format34
dc.format34
dc.language.isoeng
dc.publisherJihočeská univerzitacze
dc.rightsBez omezení
dc.subjectFreeze Substitutioncze
dc.subjectHigh Pressure Freezingcze
dc.subjectAgitationcze
dc.subjectImmunolabelingcze
dc.subjectRuBisCOcze
dc.subjectFreeze Substitutioneng
dc.subjectHigh Pressure Freezingeng
dc.subjectAgitationeng
dc.subjectImmunolabelingeng
dc.subjectRuBisCOeng
dc.titlePreparation of Specimen for Transmission Electron Microscopy using Freeze Substitution and Agitationcze
dc.title.alternativePreparation of Specimen for Transmission Electron Microscopy using Freeze Substitution and Agitationeng
dc.title.alternative-cze
dc.typebakalářská prácecze
dc.identifier.stag49787
dc.description.abstract-translatedThe quality of biological samples for Transmission Electron Microscopy prepared using High Pressure Freezing and Freeze Substitution with a novel agitation module invented by Helmuth Goldhammer and Siegfried Reipert was compared to Cells prepared without agitation and the Freeze Substitution protocol by Obornik et al. The amount of extraction was quantified via immunolabelling of RuBisCO inside the plastids of the Alveolate Chromera Velia Mechanical Damages were quantified by counting of obviously damaged and intact cells at low magnificationeng
dc.date.accepted2018-06-18
dc.description.departmentPřírodovědecká fakultacze
dc.thesis.degree-disciplineBiological Chemistrycze
dc.thesis.degree-grantorJihočeská univerzita. Přírodovědecká fakultacze
dc.thesis.degree-nameBc.
dc.thesis.degree-programBiochemistrycze
dc.description.gradeDokončená práce s úspěšnou obhajoboucze