• Přihlásit se
    Zobrazit záznam 
    •   Domovská stránka repozitáře publikací JU
    • Ostatní publikace
    • Zdravotně sociální fakulta
    • Zobrazit záznam
    •   Domovská stránka repozitáře publikací JU
    • Ostatní publikace
    • Zdravotně sociální fakulta
    • Zobrazit záznam
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Pulmonary Vein Isolation With Very High Power, Short Duration, Temperature-Controlled Lesions: The QDOT-FAST Trial

    Thumbnail
    Zobrazit/otevřít
    reddy2019.pdf (637.6Kb)
    Datum
    2019
    Autor
    Reddy, V Y.
    Grimaldi, M.
    Potter, T.
    Vijgen, J M.
    Bulava, Alan
    Duytschaever, M F.
    Martinek, M.
    Natale, A.
    Knecht, S.
    Neužil, P.
    Purerfellner, H.
    Metadata
    Zobrazit celý záznam
    Abstrakt
    Objectives: This study sought to evaluate the safety and short-term performance of a novel catheter for very high power–short duration (vHPSD) ablation in the treatment of paroxysmal atrial fibrillation. Background: The vHPSD catheter is a novel contact force–sensing catheter optimized for temperature-controlled radiofrequency ablation with microelectrodes and 6 thermocouples for real-time temperature monitoring; the associated vHPSD algorithm modulates power to maintain target temperature during 90 W, 4 s lesions. Methods: QDOT-FAST (Clinical Study for Safety and Acute Performance Evaluation of the THERMOCOOL SMARTTOUCH SF-5D System Used With Fast Ablation Mode in Treatment of Patients With Paroxysmal Atrial Fibrillation) is a prospective, multicenter, single-arm study enrolling patients with symptomatic paroxysmal atrial fibrillation indicated for catheter-based pulmonary vein isolation. Primary endpoints were short-term effectiveness (confirmation of entrance block in all targeted pulmonary veins after adenosine/isoproterenol challenge) and short-term safety (primary adverse events). Participants were screened for silent cerebral lesions by magnetic resonance imaging. Patients were followed for 3 months post-ablation. Results: A total of 52 patients underwent ablation and completed follow-up. Pulmonary vein isolation was achieved in all patients using the study catheter alone, with total procedure and fluoroscopy times of 105.2 ± 24.7 min and 6.6 ± 8.2 min, respectively. Most patients (n = 49; 94.2%) were in sinus rhythm at 3 months. Two primary adverse events were reported: 1 pseudoaneurysm; and 1 asymptomatic thromboembolism. There were no deaths, stroke, atrioesophageal fistula, pulmonary vein stenosis, or unanticipated adverse device effects. Six patients had identified silent cerebral lesions—all classified as asymptomatic without clinical or neurologic deficits. Conclusions: This first-in-human study of a novel catheter with optimized temperature control demonstrated the clinical feasibility and safety of vHPSD ablation. Procedure and fluoroscopy times were substantially lower than historical standard ablation with point-by-point catheters.
    URI
    https://dspace.jcu.cz/handle/123456789/643
    Kolekce
    • Zdravotně sociální fakulta

    DSpace software copyright © 2002-2016  DuraSpace
    Kontaktujte nás | Vyjádření názoru | Na tomto webu jsou používány pouze cookies nezbytně nutné pro zajištění fungování webu, pro které není nutné získat souhlas.
    Theme by 
    Atmire NV
     

     

    Procházet

    Vše v repozitářiTypy publikacíDle data publikováníAutořiNázvyKlíčová slovaTato kolekceDle data publikováníAutořiNázvyKlíčová slova

    Můj účet

    Přihlásit seZaregistrovat se

    DSpace software copyright © 2002-2016  DuraSpace
    Kontaktujte nás | Vyjádření názoru | Na tomto webu jsou používány pouze cookies nezbytně nutné pro zajištění fungování webu, pro které není nutné získat souhlas.
    Theme by 
    Atmire NV